Life-saving safety in the room.
How certified partition wall systems, fire-resistant glazing, solid walls, T30 doors and standard-compliant certification enable safety and transparency in interior design
Modern working environments require open and flexible spatial layouts to optimally support collaborative processes. At the same time, office buildings must meet the most stringent requirements for structural fire protection. Certified partition wall systems combine these safety requirements with high-quality architectural design. In Germany, the legal requirements are based on the State Building Regulations (LBO), the MVV TB and DIN 4102. The specific level of fire resistance required always depends on the individual building design and the regulatory requirements.
Verified safety through fire resistance classes
In order to reliably demonstrate fire safety properties once installed, system walls require appropriate building authority certification, such as general test certificates (abP) or type approvals (aBG/vBG). DIN 4102 describes the fire behaviour of building materials and defines precisely how long a component maintains its protective function in the event of a fire. For office buildings, fire-retardant constructions of Class F30 play a key role. Opaque solid walls, floor-to-ceiling fire-resistant glazing and T30 fire doors all ensure the required fire barrier in corridors, providing reliable protection for people and property in the event of an emergency.
Fire-resistant glazing: combining transparency and safety
Contemporary office architecture increasingly emphasises bright spaces, visual openness and maximum natural light. High-quality fire-resistant glazing creates unobstructed views and a sense of spaciousness without compromising the required safety functions. This creates modern working environments that combine a communicative corporate culture with the highest standards of structural safety. Where specific project requirements go beyond existing standard approvals, we explore legally compliant solutions via project-specific type approvals (vBG) based on fire tests that have already been successfully carried out and documented.
Conclusion: Fire safety as an integral part of sustainable spatial planning
Structural fire safety and modern, open-plan office architecture are by no means at odds with one another. Tested system walls, opaque solid walls and glazed fire protection elements enable architecturally sophisticated working environments that reliably meet all required fire resistance classes. Through the harmonious interplay of standard-compliant verification, forward-thinking specialist planning and flexible partition wall systems, fire safety is transformed from a mere building regulation into an integral part of future-proof spatial concepts that permanently combine a high level of safety, long-lasting functionality, a high level of well-being and aesthetic appeal.
Further reading: Media & Downloads
Make use of further information from independent specialist sources to ensure your planning of fire protection solutions and system walls is technically sound:
German Institute for Building Technology (DIBt):
Technical verification of construction products and structures
Approvals and type approvals
Federal Institute for Occupational Safety and Health: Principles for safe workplaces
Technical Regulations for Workplaces (ASR)
German Institute for Standardisation: DIN 4102 on fire behaviour, building material classes and fire resistance
Fire behaviour of building materials and components
FAQ – Fire safety for system walls
-
Modern fire-resistant system walls combine certified fire resistance (F30) with airborne sound insulation (Rw,P ≤ 52 dB) and visual transparency. Special fire-resistant laminated glass and certified sealing systems enable the creation of slim-profile glazing solutions that meet fire safety requirements without restricting light transmission or room acoustics.
-
In accordance with the LBO, the walls of fire compartments must be fire-resistant (F90), whilst the walls of necessary corridors must be fire-retardant (F30). As a general rule, this does not apply to corridors within units used for office or administrative purposes that have a usable floor area of no more than 400 m² per storey.
-
Depending on the design and intended use, various forms of building authority certification are required, such as general building authority test certificates (abP), general type approvals (aBG) or project-specific type approvals (vBG).